Количество
|
Стоимость
|
||
|
FortiAP-210B | FortiAP-220B | FortiAP-222B | |
Indoor/Outdoor Deployment | Indoor | Indoor | Indoor or Outdoor |
Number of Radios | 1 | 2 | 2 |
Number of Antennas | 2 internal | 2 internal | 4 external - N type 2 pieces - OUTDOOR DIPOLE 2.4GHZ 5DBI 180 X D20 2 pieces - OUTDOOR DIPOLE 5GHZ 7DBI 180 X D20 |
Frequency Bands (GHz)* | 2.400-2.4835, 5.150-5.250, 5.250-5.350, 5.470-5.725, 5.725-5.860 | ||
Frequency of Radio 1 | 2.4 GHz b/g/n or 5 GHz a/n (Selectable) | 2.4 GHz b/g/n or 5 GHz a/n (Selectable) | 5 GHz a/n |
Frequency of Radio 2 | - | 2.4 GHz b/g/n | 2.4 GHz b/g/n |
Tx/Rx Streams | 2x2 MIMO dual stream – 300 Mbps/Radio | 2x2 MIMO dual stream – 300 Mbps/Radio (600 Mbps Total) | 2x2 MIMO dual stream – 300 Mbps/Radio (600 Mbps Total) |
Ethernet Port | 1 x 10/100/1000 | 1 x 10/100/1000 | 1 x 10/100/1000 |
Console Port | 1 | 1 | 0 |
Power over Ethernet (PoE) | 802.3af (15.4W) | 802.3af (15.4W) | PoE power injector supplied, or 802.3at (30W) |
WME Multimedia Extensions | Yes (4 priority queues for voice, video, data and background traffc) | ||
Simultaneous SSIDs | 8 - 7 for client access, 1 for monitoring | 16 - 14 for client access, 2 for monitoring | 16 (14 for client access, 2 for monitoring) |
Maximum Transmission Power | 17dBm (50mW) | 17dBm (50mW) | 27dBm (500mW) hardware capable – limited by software for regulatory compliance |
Physical Security | Kensington Lock | Kensington Lock | Concrete and pole mount |
Mean Time Between Failures | Kensington Lock | Kensington Lock | 305,420 hours |
Dimensions | |||
Height | Height 1.1 in (2.7 cm), Width 6.4 in (16.3 cm), Length 5.1 in (12.9 cm) | Height 1.1 in (2.7 cm), Width 6.4 in (16.3 cm), Length 5.1 in (12.9 cm | 2.75 in (7 cm) x 7.75 in (19.7 cm) x 10 in (25.4cm) |
Weight | 11.2 oz (317 g) | 11.3 oz (320 g) | 5 lbs (2.3 Kg) |
Mount | Wall or Ceiling | Wall or Ceiling | Wall or Pole with mounting kit |
Environment | |||
Power Adaptor | Adaptor Input 100-240V 50/60Hz 0.6A Output: 12V DC 1.5A –center positive | POE injector supplied with AC power source. | |
Humidity | 10% to 90% non condensing | 0 to 100% | |
Operating Temperature | 32 – 104 ˚F (0 – 40 ˚C) | -4 – 140 ˚F (-20 – 60 ˚C) | |
Storage Temperature | -4 to 158 ˚F (-25 to 70 ˚C) | -4 – 140 ˚F (-20 – 60 ˚C) | |
Target Application | Dedicated AP w/background scan or dedicated air monitor | Simultaneous AP and dedicated air monitor | Warehouses, outdoor areas, industrial settings, and other harsh environments. |
Directives | Low Voltage Directive RoHS |